Technical data and characteristics
6.2 Motor overview/Motor Module assignment/power cables
1FT2 synchronous motors for SINAMICS S120
74 Configuration Manual, 03/2021, A5E50645584B AA
Recommended Motor Module
For every motor, Chapter "Motor overview/Motor Module assignment/power cables
(Page 74)" recommends a Motor Module corresponding to its stall (starting) current.
The maximum torque that can be temporarily achieved using this Motor Module is listed in
the tables of this manual as M
max inv.
• When configuring intermittent or overload operation, check whether a larger Motor
Module is required to provide the necessary peak current.
Tolerance data
The characteristic data listed in the data sheets are subject to a certain amount of scatter. The
following tolerances apply to the characteristic data:
The torque-speed characteristics specified in the following chapter relate to the nominal
values at operating temperature.
6.2 Motor overview/Motor Module assignment/power cables
On the following pages, you can find the suitable SINAMICS Motor Modules and MOTION-
CONNECT power cables for the 1FT2.
SINAMICS Motor Module S120 Booksize, DC link voltage 510 V DC to 720 V DC, line voltage 3 AC
380 V to 480 V
Example of an article number for a SINAMICS Motor Module
The following table describes the options that can be selected for the SINAMICS Motor
Module.
Position in the article number
SINAMICS Motor Modules S120
Booksize (example)