Converter data sheets and characteristics
4.1 Forced ventilation
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
50 Commissioning Manual, 10/2014, 610.40106.40
Additional parameterization
Booksize 60 A
400 V
480 V
Motor type selection
p300
1
1
Line resistance
p352
0.12
0.12
Current controller adaptation, starting point
KP
p391 8 8
Current controller adaptation, starting point
KP adapted
p392 10 10
Current controller adaptation, P gain adapta-
tion
p393 70 70
Current limit
p640
67.8
67.8
Maximum rotation speed
p1082
24,000
24,000
Torque limit, upper/motoring
p1520
19
19
Torque limit, lower/regenerative
p1521
-19
-19
Power limit, motoring
p1530
24.4
26.5
Power limit, regenerative
p1531
-24.4
-26.5
Maximum field-generating current
p1603
90
90
Pulse frequency setpoint
p1800
8
8
Modulator configuration
p1810
"&H800"
"&H800"
Current controller P gain
p1715
2.2
2.2
Reference speed reference frequency
p2000
24,000
24,000
Reference current
p2002
67.8
67.8
Reference torque
p2003
19
19
Hysteresis speed n_act > n_max
p2162
480
480