EasyManuals Logo

Siemens SIMOTICS S-1FL6 Getting Started

Siemens SIMOTICS S-1FL6
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Getting Started
A5E36037886-003, 04/2017
25
Specific technical data
SINAMICS V90 200 V variant
Order No.
6SL3210-5FB...
10-1UA0
10-2UA0
10-4UA1
10-8UA0
11-0UA1
11-5UA0
12-0UA0
Frame size
FSA
FSA
FSB
FSC
FSD
FSD
FSD
Rated output current (A)
1.2
1.4
2.6
4.7
6.3
10.6
11.6
Max. output current (A)
3.6
4.2
7.8
14.1
18.9
31.8
34.8
Max. supported motor power (kW)
0.1
0.2
0.4
0.75
1.0
1.5
2
Power loss
1)
Main circuit (W)
8
15
33
48
65
105
113
Regenerative resistor
(W)
5 5 7 9 13 25 25
Control circuit (W)
16
16
16
16
16
18
18
Total (W)
29
36
56
73
94
148
156
Output frequency (Hz)
0 to 330
Power sup-
ply
Voltage/frequency FSA, FSB and FSC: single phase/three phase 200 VAC to 240 VAC, 50/60 Hz
FSD: three phase 200 VAC to 240 VAC, 50/60 Hz
Permissible voltage
fluctuation
-15% to +10%
Permissible frequency
fluctuation
-10% to +10%
Permissible supply con-
figuration
TN, TT, IT
Rated input
current (A)
1-phase
2.5
3.0
5.0
10.4
-
-
-
3-phase 1.5 1.8 3.0 5.0 7.0 11.0 12.0
Power supply
capacity
(kVA)
1-phase
0.5
0.7
1.2
2.0
-
-
-
3-phase 0.5 0.7 1.1 1.9 2.7 4.2 4.6
Inrush current (A)
8.0
Cooling method
Self-cooled
Fan-cooled
Mechanical
design
Outline dimensions (W x
H x D, mm)
45 x 170 x 170 55 x 170
x 170
80 x 170
x 195
95 x 170 x 195
Weight (kg)
1.1
1.3
1.95
2.35
2.4
1)
The values here are calculated at rated load.

Table of Contents

Other manuals for Siemens SIMOTICS S-1FL6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS S-1FL6 and is the answer not in the manual?

Siemens SIMOTICS S-1FL6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS S-1FL6
CategoryServo Drives
LanguageEnglish

Related product manuals