WARNING
Danger to life for wearers of active implants due to magnetic and electrical elds
Electric motors pose a danger to people with active medical implants, e.g. cardiac stimulators,
who come close to the motors.
• If you are aected, stay a minimum distance of 300 mm from the motors (tripping threshold
for static magnetic elds of 0.5 mT according to the Directive 2013/35/EU).
In conjunction with a suitable drive system, the built-in torque motors can be used as direct drive
for the following machine applications:
• Rotary axes
• Rotary tables, rotary indexing machines, subassemblies
• Turret indexing and drum indexing for single-spindle and multi-spindle machines
• Dynamic tool magazines
• Rotating spindles
• Roller and cylinder drives
• Infeed and handling axes
WARNING
Injury and material damage by not observing machinery directive 2006/42/EC
There is a risk of death, serious injury and/or material damage if machinery directive
2006/42/EC is not carefully observed.
• The products included in the scope of delivery are exclusively designed for installation in a
machine. Commissioning is prohibited until it has been fully established that the end
product conforms with machinery directive 2006/42/EC.
• Please observe all safety instructions and provide these safety instructions to the end user.
Avoiding violation of protective rights
Carefully observe all national and international license terms when operating direct motors so
that no patent rights are violated.
Introduction
1.5Important product information
1FW6 built-in torque motors
Operating Instructions, 09/2022, A5E52220812B AA 15