Note
Lifting bars
The lifting bars are not included in the scope of delivery.
WARNING
Inadequately dimensioned lifting rods
Inadequately dimensioned lifting rods are liable to bend or break. The drive could drop off the
crane. This can result in death, serious injury or material damage.
Use suitable lifting rods for transporting. The weight of the cabinet is indicated on the rating
plate.
NOTICE
Improper lifting
If the transport unit is lifted incorrectly, this can damage the decorative trim, cabinet doors,
or fans.
Protect the cabinet and protruding parts against damage.
Always lift the transport units with the appropriate spreading devices or hoisting tackle.
Procedure
1. If there are several holes, select which holes to use based on the center of gravity.
2. Push the lifting bars through the holes.
Figure 4-6 Lifting bar label
3. Place the sling ropes on the lifting bars so they are close to the cabinet. Secure the ends
of the lifting bars using the splint.
Figure 4-7 Securing the lifting rods
Preparations for use
4.4 Transportation
SINAMICS GL150 6SL38503UM114PA0Z