Controlling the safety functions
5.4 Activating "SBC" via the Safe Brake Adapter
Safety Integrated
Function Manual, 08/2023, A5E03264275A
91
WARNING
Exceeding the permissible cable length of the brake control
If the permissible cable length of the brake control is exceeded this can result in death or
serious injury in the event of an error.
The maximum permissible cable length of 300 m between the 230 V AC Safe Brake
Adapter and the brake must be carefully maintained.
To accurately calculate the maximum cable length, see the SINAMICS Low Voltage
Configuration Manual on the customer DVD supplied with the device.
Table 5- 28 Terminal strip -X15, fast de-energization
Connection
Signal
Description
-X15.1
AUX1
Supply voltage: 230 V AC
Current consumption: 2 A
-X15.2
AUX2
Max. connectable cross-section 2.5 mm
2
Spare fuse
The type of spare fuse is as follows: 2 A, time-lag.
Note
Correctly mounting the housing cover after replacing a fuse
An adhesive label is provided on the housing cover indicating the position of the connector.
Mount the cover in the correct position so that the inscription of the label matches the actual
connectors.