The symmetrical interference is minimized by means of twisted cables (outgoing/incoming
conductors).
In general, the shield should be applied at both ends of the shield support bar.
The digital outputs of the TM15 are continued short-circuit proof. The logical status of the
outputs can be read back.
70
3
0
0
*URXSV
7UDQVIRUPHU
0RWRU
,QVWUXPHQWDWLRQDQGFRQWURO
Figure 8-7 Digital signal output to the system I/O
Designation Voltage values
Rated value for output voltage (DC) 24 V
Output current per channel 0.5 A
Cumulative current of outputs (per group)
To 40° C, max. 4 A
To 50° C, max. 3 A
To 60° C, max. 2 A
Operation
8.5 Functions
SINAMICS SM150 6SL3845-7NN46-7AA2
120 Operating Instructions Rev.201910281345 EXAMPLE