Connection example: HTL encoder, bipolar, with reference signal
This example shows the connection assignment on the sensor module. The terminals of the
sensor module are wired to the customer terminal strip. For further information, see the circuit
manual.
*URXQGHQFRGHUVXSSO\
(QFRGHUSRZHUVXSSO\9
&75/
7UDFN%
7UDFN%
7UDFN$
7UDFN$
*URXQG
5HIHUHQFHVLJQDO5
5HIHUHQFHVLJQDO5
;
;
.
.
0
8E
.
.
.
.
Figure 6-7 Connection example: HTL encoder, bipolar, with reference signal
Use a bipolar connection. The unipolar connection should only be employed when the encoder
type being used does not provide push-pull signals.
6.5.8 Interconnecting optional connections
Depending on the range of options installed, further connections have to be interconnected.
Detailed information about interconnecting these options with the interfaces is provided in the
circuit manual.
6.5.9 Connecting the re-cooling unit to the drive
Connect the cable provided for the cooling unit to the corresponding interfaces on the drive and
the cooling unit. Further details are contained in the circuit diagram of the drive and the re-
cooling unit.
Electrical connection
6.5 Connection
SINAMICS SM150 6SL3845-7NN46-7AA2
98 Operating Instructions Rev.201910281345 EXAMPLE