Figure 9-8 Changing the filter in the roof assembly
1. Release the four screws .
2. Release the two screws . Remove the filter frame.
3. Remove the filter .
If there is a slight amount of dirt, clean the filter mat at a suitable location. Depending on the
degree of pollution, you can also clean the filter mats using a vacuum cleaner. If the filter mat
is damaged, or the frequency of alarms increases, dispose of the dirty filter mat in the correct
fashion. Use a new filter mat
4. Place a new filter in the frame .
5. Reattach the frame of the filter and cover.
9.4.7 Maintaining the fan
CAUTION
Injury caused by rotating fan
If the drive is equipped with a temperature-controlled fan, the fan can run on even if the power
section is switched off. You can be injured if you touch the fan.
Wait until the fan has shut down and has come to a stop.
Maintenance
9.4 Inspection and maintenance
SINAMICS SM150 6SL3845-7NN46-7AA2
148 Operating Instructions Rev.201910281345 EXAMPLE