r0050 Active command data set (CDS)
Display of the active command data set (Command Data Set, CDS)
Bit Signal name 0-signal 1-signal
00 CDS effective, bit 0 No Yes
01 CDS effective, bit 1 No Yes
02 CDS effective, bit 2 No Yes
03 CDS effective, bit 3 No Yes
You can find additional notes in the parameter description of parameters p0810, p0811, r0836 in the List Manual.
The command data set selected via the binector inputs (e.g. p0810) is displayed via r0836.
Diagnostic parameters for digital inputs/outputs
r0721 CU digital inputs terminal actual value
Display of the actual value on the digital inputs
Bit Signal name 0-signal 1-signal
00 DI 0 (X122.1) Low High
01 DI 1 (X122.2) Low High
02 DI 2 (X122.3) Low High
03 DI 3 (X122.4) Low High
04 DI 4 (X132.1) Low High
05 DI 5 (X132.2) Low High
06 DI 6 (X132.3) Low High
07 DI 7 (X132.4) Low High
08 DI/DO 8 (X122.7) Low High
09 DI/DO 9 (X122.8) Low High
10 DI/DO 10 (X122.10) Low High
11 DI/DO 11 (X122.11) Low High
12 DI/DO 12 (X132.7) Low High
13 DI/DO 13 (X132.8) Low High
14 DI/DO 14 (X132.10) Low High
15 DI/DO 15 (X132.11) Low High
If a DI/DO is parameterized as output (p0728.x = 1), then r0721.x = 0 is displayed.
DI: Digital input
DI/DO: Bidirectional digital input/output
r0747 CU digital outputs status
Display of the digital output status
Bit Signal name 0-signal 1-signal
08 DI/DO 8 (X122.7) Low High
09 DI/DO 9 (X122.8) Low High
10 DI/DO 10 (X122.10) Low High
11 DI/DO 11 (X122.11) Low High
12 DI/DO 12 (X132.7) Low High
13 DI/DO 13 (X132.8) Low High
Operation
8.6 Fault and system messages
SINAMICS SM150 6SL3845-7NN46-7AA2
Operating Instructions Rev.201910281345 EXAMPLE 131