Commissioning 
  5.5 Quick commissioning 
SINAMICS V20 Inverter 
Operating Instructions, 07/2012, A5E03728167 
47 
Parameter  Description  Factory 
default 
Default for 
Cn005 
Remarks 
P0704[0]  Function of digital input 4  15  9  Fault acknowledgement 
P1016[0]  Fixed frequency mode  1  1  Direct selection mode 
P1020[0]  BI: Fixed frequency selection bit 0  722.3  722.1  DI2 
P1021[0]  BI: Fixed frequency selection bit 1  722.4  722.2  DI3 
P1001[0]  Fixed frequency 1  10  10  Fixed speed 1 
P1002[0]  Fixed frequency 2  15  15  Fixed speed 2 
P1074[0]  BI: Disable additional setpoint  0  1025.0  FF disables the additional setpoint 
P0771[0]  CI: Analog output  21  21  Actual frequency 
P0731[0]  BI: Function of digital output 1  52.3  52.2  Inverter running 
P0732[0]  BI: Function of digital output 2  52.7  52.3  Inverter fault active 
Connection macro Cn006 - External push button control 
Note that the command sources are pulse signals. 
OK
M
10V  AI1  AI2   0V    DI1  DI2  DI3  DI4  DIC  24V  0V
AO + AO- DO1 +   DO1 - P +  N-
DO2
0V 0V
0~20mA=
0~50 /60 Hz
220V
N
2))KROG
21SXOVH
023XS
023GRZQ
)DXOW5XQQLQJ6SHHG
   
 
Connection macro settings: 
 
Parameter  Description  Factory 
default 
Default for 
Cn006 
Remarks 
P0700[0]  Selection of command source  1  2  Terminals as command source 
P1000[0]  Selection of frequency  1  1  BOP MOP 
P0701[0]  Function of digital input 1  0  2  OFF1 / hold 
P0702[0]  Function of digital input 2  0  1  ON pulse 
P0703[0]  Function of digital input 3  9  13  MOP up pulse 
P0704[0]  Function of digital input 4  15  14  MOP down pulse 
P0727[0]  Selection of 2 / 3-wire method  0  3  3-wire 
ON pulse + OFF1 / HOLD + 
Reverse 
P0771[0]  CI: Analog output  21  21  Actual frequency 
P0731[0]  BI: Function of digital output 1  52.3  52.2  Inverter running