Commissioning
5.6 Function commissioning
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
59
5.6 Function commissioning
5.6.1 Overview of inverter functions
The list below provides an overview of the main functions that the SINAMICS V20 supports.
For detailed description of individual parameters, see Chapter "
Parameter list (Page 117)".
User access level control (P0003)
50 / 60 Hz customization (P0100) (see also "
Setting the 50 / 60 Hz selection menu
(Page
37)".)
Text menu display (P8553) (see also "
Setting motor data (Page 40)" and "Setting
common parameters (Page
55)".)
Protection of user-defined parameters (P0011, P0012, P0013)
Pre-configured connection macros and application macros (P0507, P0717) (see also
"
Setting connection macros (Page 41)" and "Setting application macros (Page 52)".)
Energy consumption monitoring (r0039, P0040, P0042, P0043)
Inverter keep-running operation (P0503)
Motor frequency display scaling (P0511, r0512)
DI terminal function control (P0701 ... P0713, r0722, r0724)
AI terminal function control (P0712, P0713, r0750 ... P0762)
DO terminal function control (P0731, P0732, P0747, P0748)
AO terminal function control (P0773 ... r0785)
2 / 3 wire control (P0727)
Parameter cloning (P0802 ... P0804, P8458) (see also "
Parameter Loader (Page 247)".)
Command data set (CDS) and inverter data set (DDS) (r0050, r0051, P0809 ... P0821)
Various stop mode selection (P0840 ... P0886, see also "
Selecting the stop mode
(Page
61)".)
Command and setpoint source selection (P0700, P0719, P1000 ... r1025, P1070 ...
r1084)
Fault and warning reaction setting (r0944 ... P0952, P2100 ... P2120, r3113, P3981)
Motorized potentiometer (MOP) mode selection (P1031 ... r1050)
JOG mode operation (P1055 ... P1061, see also "
Running the inverter in JOG mode
(Page
63)".)
Skip frequency and resonance damping (P1091 ... P1101, P1338)
Dual ramp operation (r1119 ... r1199, P2150 ... P2166, see also "
Setting the dual ramp
function (Page
103)".)
Flying start (P1200 ... r1204, see also "
Setting the flying start function (Page 92)".)
Automatic restart (P1210, P1211, see also "
Setting the automatic restart function
(Page
93)".)

Table of Contents