2.5 AC5100 (ACC-G1)
Refer to AC5100 Installation Manual for details.
1. Connect an Ethernet cable to the ACC. For details on configuration, see the
respective hardware manual.
2. From the Windows Command Prompt dialog (Select Start > Run > cmd)
download the firmware to the ACC using the following command from the
firmware directory:
D:\firmware>tftp i xxx.xxx.xxx.xxx put [filename] image where:
xxx.xxx.xxx.xxx = the ACC’s IP address [filename] = the filename of the firmware
Default ACC IP Address: 192.168.1.250
Default ACC Subnet Mask: 255.255.255.0
Once download is complete, boot the ACC using the boot command in the
HyperTerminal window. Once the initial version of firmware has been downloaded,
new versions can be updated using SiPass integrated.
2.5.1 Restoring Default Network and Password Settings
The ACC G1 does not have a "set defaults" jumper. It can be recovered as below:
1. Downgrade to a 2.65 build.
2. Use the "set defaults" command from the Telnet console or DIAG port
connected to a serial port on a computer. (The default IP address is now:
192.168.1.250)
3. Reset the ACC.
4. Login via the DIAG port. Default login credentials are: SIEMENS/spirit
5. Reset the network settings.
6. Then upgrade back to MP 2.70, login and change the password when asked.