EasyManua.ls Logo

Siemens siprotec 7SD5 - Page 646

Siemens siprotec 7SD5
698 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A Appendix
646
7SD5 Manual
C53000-G1176-C169-1
1137 R (secondary single ended)
(Rsec single. =)
Fault Locator VI on off
1138 X (secondary single ended)
(Xsec single. =)
Fault Locator VI * on off
1143 BCD Fault location [1%] (BCD
d[1%])
Fault Locator OUT * * LED BO
1144 BCD Fault location [2%] (BCD
d[2%])
Fault Locator OUT * * LED BO
1145 BCD Fault location [4%] (BCD
d[4%])
Fault Locator OUT * * LED BO
1146 BCD Fault location [8%] (BCD
d[8%])
Fault Locator OUT * * LED BO
1147 BCD Fault location [10%] (BCD
d[10%])
Fault Locator OUT * * LED BO
1148 BCD Fault location [20%] (BCD
d[20%])
Fault Locator OUT * * LED BO
1149 BCD Fault location [40%] (BCD
d[40%])
Fault Locator OUT * * LED BO
1150 BCD Fault location [80%] (BCD
d[80%])
Fault Locator OUT * * LED BO
1151 BCD Fault location [100%] (BCD
d[100%])
Fault Locator OUT * * LED BO
1152 BCD Fault location valid (BCD
dist. VALID)
Fault Locator OUT * * LED BO
1305 >Earth Fault O/C Block 3I0>>>
(>EF BLK 3I0>>>)
Earth Fault O/C SP ON
OFF
**LEDBIBO16651Yes
1307 >Earth Fault O/C Block 3I0>>
(>EF BLOCK 3I0>>)
Earth Fault O/C SP ON
OFF
**LEDBIBO16671Yes
1308 >Earth Fault O/C Block 3I0> (>EF
BLOCK 3I0>)
Earth Fault O/C SP ON
OFF
**LEDBIBO16681Yes
1309 >Earth Fault O/C Block 3I0p (>EF
BLOCK 3I0p)
Earth Fault O/C SP ON
OFF
**LEDBIBO16691Yes
1310 >Earth Fault O/C Instantaneous
trip (>EF InstTRIP)
Earth Fault O/C SP ON
OFF
ON
OFF
* LED BI BO 166 10 1 Yes
1311 >E/F Teleprotection ON (>EF
Teleprot.ON)
Teleprot. E/F SP * * * LED BI BO
1312 >E/F Teleprotection OFF (>EF
TeleprotOFF)
Teleprot. E/F SP * * * LED BI BO
1313 >E/F Teleprotection BLOCK (>EF
TeleprotBLK)
Teleprot. E/F SP ON
OFF
* * LED BI BO 166 13 1 Yes
1318 >E/F Carrier RECEPTION,
Channel 1 (>EF Rec.Ch1)
Teleprot. E/F SP on
off
on * LED BI BO 166 18 1 Yes
1319 >E/F Carrier RECEPTION,
Channel 2 (>EF Rec.Ch2)
Teleprot. E/F SP on
off
on * LED BI BO 166 19 1 Yes
1320 >E/F Unblocking: UNBLOCK,
Channel 1 (>EF UB ub 1)
Teleprot. E/F SP ON
OFF
ON * LED BI BO 166 20 1 Yes
1321 >E/F Unblocking: BLOCK,
Channel 1 (>EF UB bl 1)
Teleprot. E/F SP ON
OFF
ON * LED BI BO 166 21 1 Yes
1322 >E/F Unblocking: UNBLOCK,
Channel 2 (>EF UB ub 2)
Teleprot. E/F SP ON
OFF
ON * LED BI BO 166 22 1 Yes
1323 >E/F Unblocking: BLOCK,
Channel 2 (>EF UB bl 2)
Teleprot. E/F SP ON
OFF
ON * LED BI BO 166 23 1 Yes
1324 >E/F BLOCK Echo Signal (>EF
BlkEcho)
Teleprot. E/F SP ON
OFF
ON * LED BI BO 166 24 1 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation
www . ElectricalPartManuals . com

Table of Contents

Other manuals for Siemens siprotec 7SD5

Related product manuals