Appendix
A.8 Information List
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
717
1356 E/F 3I0> PICKED UP (EF 3I0>
Pickup)
Earth Fault O/C OUT * on * LED BO
1357 E/F 3I0p PICKED UP (EF 3I0p
Pickup)
Earth Fault O/C OUT * on * LED BO
1358 E/F picked up FORWARD (EF
forward)
Earth Fault O/C OUT * on * LED BO 166 58 2 No
1359 E/F picked up REVERSE (EF re-
verse)
Earth Fault O/C OUT * on * LED BO 166 59 2 No
1361 E/F General TRIP command (EF
Trip)
Earth Fault O/C OUT * * * LED BO 166 61 2 No
1362 Earth fault protection: Trip 1pole
L1 (E/F Trip L1)
Earth Fault O/C OUT * on * LED BO 166 62 2 Yes
1363 Earth fault protection: Trip 1pole
L2 (E/F Trip L2)
Earth Fault O/C OUT * on * LED BO 166 63 2 Yes
1364 Earth fault protection: Trip 1pole
L3 (E/F Trip L3)
Earth Fault O/C OUT * on * LED BO 166 64 2 Yes
1365 Earth fault protection: Trip 3pole
(E/F Trip 3p)
Earth Fault O/C OUT * on * LED BO 166 65 2 Yes
1366 E/F 3I0>>> TRIP (EF 3I0>>>
TRIP)
Earth Fault O/C OUT * on * LED BO 166 66 2 No
1367 E/F 3I0>> TRIP (EF 3I0>> TRIP) Earth Fault O/C OUT * on * LED BO 166 67 2 No
1368 E/F 3I0> TRIP (EF 3I0> TRIP) Earth Fault O/C OUT * on * LED BO 166 68 2 No
1369 E/F 3I0p TRIP (EF 3I0p TRIP) Earth Fault O/C OUT * on * LED BO 166 69 2 No
1370 E/F Inrush picked up (EF Inrush-
PU)
Earth Fault O/C OUT * on off * LED BO 166 70 2 No
1371 E/F Telep. Carrier SEND signal,
Phase L1 (EF Tele SEND L1)
Teleprot. E/F OUT on on * LED BO 166 71 1 No
1372 E/F Telep. Carrier SEND signal,
Phase L2 (EF Tele SEND L2)
Teleprot. E/F OUT on on * LED BO 166 72 1 No
1373 E/F Telep. Carrier SEND signal,
Phase L3 (EF Tele SEND L3)
Teleprot. E/F OUT on on * LED BO 166 73 1 No
1374 E/F Telep. Block: carrier STOP
signal L1 (EF Tele STOP L1)
Teleprot. E/F OUT * on * LED BO 166 74 2 No
1375 E/F Telep. Block: carrier STOP
signal L2 (EF Tele STOP L2)
Teleprot. E/F OUT * on * LED BO 166 75 2 No
1376 E/F Telep. Block: carrier STOP
signal L3 (EF Tele STOP L3)
Teleprot. E/F OUT * on * LED BO 166 76 2 No
1380 E/F Teleprot. ON/OFF via BI (EF
Tele O N / off B I)
Teleprot. E/F IntSP on
off
**LEDBO
1381 E/F Teleprotection is switched
OFF (EF Telep. OFF)
Teleprot. E/F OUT on
off
* * LED BO 166 81 1 Yes
1384 E/F Telep. Carrier SEND signal
(EF Tele SEND)
Teleprot. E/F OUT on on * LED BO 166 84 2 No
1386 E/F Telep. Transient Blocking (EF
TeleTransBlk)
Teleprot. E/F OUT * on * LED BO 166 86 2 No
1387 E/F Telep. Unblocking: FAILURE
Channel 1 (EF TeleUB Fail1)
Teleprot. E/F OUT on
off
* * LED BO 166 87 1 Yes
1388 E/F Telep. Unblocking: FAILURE
Channel 2 (EF TeleUB Fail2)
Teleprot. E/F OUT on
off
* * LED BO 166 88 1 Yes
1389 E/F Telep. Blocking: carrier STOP
signal (EF Tele BL STOP)
Teleprot. E/F OUT * on * LED BO 166 89 2 No
1390 E/F Tele.Blocking: Send signal
with jump (EF Tele BL Jump)
Teleprot. E/F OUT * * * LED BO 166 90 2 No
1401 >BF: Switch on breaker fail pro-
tection (>BF on)
Breaker Failure SP * * * LED BI BO
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation