EasyManua.ls Logo

Siemens SITRANS F US SONOFLO SONO 3000 - Installation Steps; Cable Connections; Mounting Components

Siemens SITRANS F US SONOFLO SONO 3000
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 SFIDK.PS.029.Q3.02
SITRANS F US SONOFLO
®®
®®
®
SONO 3000 SONO 3000 Ex-dSignal converters
Enclosure IP 67
19" insert 19" insert
IP 67
IP 00 IP 65
Mounting Compact or separate 19" rack wall mounting and Compact or separate
wall mounting panel mounting wall mounting
Accuracy (error limit) 0.5% of actual flow
Materials Polyamid ALU ABS Plastic ASTM 316
Outputs 1 current 3 current 3 current 1 current
1 frq./pulse 2 frq./pulse 2 frq./pulse 1 frq./pulse
1 relay 2 relays 2 relays 1 relay
Display/counter Alphanumeric: flow, quantity, error, mass flow, sound velocity, etc.
Language English, German, French
Approval Can be used with any EEx-approved sensor SONO 3100
and SONOKIT, when the SONO 3000 EEx de [ia/ib] IIC T6
is placed in safe area
Supply voltage
115/230 V a.c.
24 V a.c./d.c.
24 V a.c./d.c.
Sensor
Size
[[
[[
[mm
]]
]]
] DN 50 - DN 300 DN 100 - DN 1200 DN 200 - DN 4000
Connection examples DIN 2501
ANSI B 16.5 150 lbs RF None
ANSI B 16.5 300 lbs RF
Pressure
[[
[[
[bar
]]
]]
] PN 10, PN 16, PN 6, PN 10, PN 16,
PN 40 PN 25, PN 40 Max. PN 40
Class 150, Class 300 Class 150, Class 300
Media temperature
max.
[[
[[
[°C
]]
]]
]
160 200 200
Transducer SONO 3200
SONO 3200
Integrated transducers O-ring type
O-ring type
Flange transducers
Enclosure IP 67 IP 68 IP 68
Approvals EEx d II C T3-T6 EEx d IIC T2-T6 EEx d IIC T3-T6
SONO 3100SONO 3300
SONOKITStainless and
mild steel
Extended program
Mild steel
Standard program
Siemens Flow Instru-
ments range of ultra-
sonic flowmeters

Table of Contents