6 SFIDK.PS.029.Q3.02
Tech. data
2. Technical data
SITRANS F US SONOFLO
®®
®®
®
Enclosure IP 67
Enclosure IP 20 to IEC 529 and DIN 40050
Material Standard 19" insert in aluminium/steel
(DIN 41494)
Mechanical vibration 1G 1-800 Hz sinusoidal in all directions
to IEC 68-2-6
Ambient temperature Operation: +0 °C to +55 °C
Storage: 40 °C to +85 °C
Supply voltage and power 115/230 V a.c. +10% to 15%, 50-60 Hz,
consumption 10-20 VA
PE, N and L
Enclosure IP 20,
front of panel
2.2 Signal converter
SONO 3000
Terminal
connection
Analog output Individually galvanically isolated,
isolation voltage 500 V
31 and 32
Measurement of: (optional via menu) Volume flow, sound velocity 33 and 34
Current 0-20 mA or 4-20 mA 35 and 36
Load < 800 ohm
Time constant 0.8-30 s adjustable
Frequency/pulse output Individually galvanically isolated,
50, 51 and 52
isolation voltage 500 V
Measurement of: (optional via menu) Volume flow, sound velocity,
54, 55 and 56
total volume, total mass
Frequency 0-10 kHz
Time constant 0.8-30 s adjustable
Pulse width 50 µs, 500 µs, 5 ms, 20 ms, 50 ms, 100 ms,
500 ms, 1 s, 5 s
Active: Output mode 24-30 V d.c./max. 25 mA, (50 µs to 5 s)
(50 ms E.Mech., max. 75 mA if F < Hz)
24-30 V d.c./max. 50 mA, (500 Hz to 10 kHz)
Passive: Output mode 5-30 V d.c.
Max. current 200 mA
Output mode Output can be either active or passive
depending on electrical connection
Relay Change-over relay (error indication, 44, 45 and 46
flow direction, sound velocity limit)
Load 42 V, 0.5 A
Time constant/Hysteresis 5 s/0.5 % F.S.O.
Cut off: Low flow 0-9.9 % F.S.O.
Supply voltage and 115-230 V a.c. +10% to 15%, 50-60 Hz,
power consumption 10-20 VA
PE, N and L
24 V d.c. +25/15%, 24 V a.c. ±15%, 10 VA, PE, N and L
cable impedans < 10 ohm at 24 V PE, 1 and 2
Internal counters (totalizers) Two internal counters. Selectable uni- or
bidirectional counting (Net flow)
Measurement of Total volume
Display Back-lit with alphanumerical text, 2 x 16 digits
for indication of: measured values, totalization,
settings, error codes and alarms
Enclosure IP 67 to IEC 529
Material Fibre glass reinforced polyamide
Mechanical vibration 2G 1-800 Hz sinusoidal in all directions
to IEC 68-2-6
Ambient temperature Operation: 20 °C to +55 °C
Storage: 40 °C to +85 °C
CE-mark EMC CENELEC Emission Immunity
EN 50081-1 EN 50082-2
Low voltage According to EN 60730

Table of Contents

Other manuals for Siemens SITRANS F US SONOFLO SONO 3000