SFIDK.PS.029.Q3.02 47
7. Starting up
Starting up
SITRANS F US SONOFLO
®®
®®
®
Frq. 2/Pulse 2 Off Volume flow, mass flow, sound velocity, off
Frq. 2/Pulse 2 direction Unidirectional Unidirectional, bidirectional
Frq. 2/Pulse 2 Pulse Frq., pulse
Pulse 2 unit m
3
L, L × 10, L × 100, m
3
, m
3
× 10, m
3
× 100,
UG × 0,1, UG, UG × 10, UG × 100, MUG,
kg, kg × 10, kg × 100, ton, lb, lb × 10, lb × 100
Pulse 2 Volume/pulse 1 -
Pulse 2 Width 50 ms 50 µs, 500 µs, 50 ms E. Mech., 500 ms, 1 s, 5 s
Frq. 2 frequency 10 kHz 500 Hz, 1 kHz, 5 kHz, 10 kHz
Frq. 2 time constant 5 s 0,8 - 30 s
Relay 1 Error Flow dir., sound limit, error, off
Relay 2 Off Flow dir., sound limit, off
SENSOR Default settings with-
CHARACTERISTIC out SENSORPROM
®
unit
Calibration choice Wet Wet, auto
Calibration constant 0.392
Correction factor 1 0.8000 - 1.2000
Cable length 1 1 - 500
Viscosity unit mm
2
/s mm
2
/s, cSt.
Viscosity 1 -
Pipe diameter 0.398
Pipe geometry unit m m, inch
Pipe surface roughness 0.0004 0.0000 - 0.0100
No. of tracks 2 1, 2, 4
Track 1-track On On, off
Track 1-track length 0.46
Track 1-track angle 60
Track 1 Displacement 0.179
Track 2-track On On, off
Track 2-track length 0.46
Track 2-track angle 60
Track 2 Displacement 0.179
Track 3-track Off On, off
Track 3-track length 0.46
Track 3-track angle 60
Track 3 Displacement 0.179
Track 4-track Off On, off
Track 4-track length 0.46
Track 4-track angle 60
Track 4 Displacement 0.179
RESET MODE
Zero adjustment Factory Factory, new auto, old auto
OPERATOR MENU
SETUP Volume flow (Cannot be deselected)
Error pending Volume flow
Volume flow %
Mass flow
Mass flow %
Density
Sound velocity
Totalizer 1
Totalizer 1 reset
Totalizer 2
Totalizer 2 reset
Volume flow max.
Mass flow max.
Sound velocity min.
Sound velocity max.
Sensor type
Sensor size
Signal converter type
Error log
Error pending
Default settings Settings available
Table 1
(continued)