Wall mount
Note
The following example is shown in the Reflect mount sensor configuration.
Connect sensor cables to the wall mounted transmitter as follows:
1. Fill connector end with Super Lube prior to connecting.
2. Apply Super Lube to the internal threads at the large end of the thread connector.
3. Observing the upstream and downstream orientation , connect upstream sensor cable to the transmitter port (1A)
and make connection snug.
4. Connect the downstream sensor cable
to the transmitter port (1B) and make connection snug.
Wall mounted transmitter
Downstream sensor cable (1B) Path 1
Upstream sensor cable (1A) Path 1
Sensors
Flow direction
Figure 4-2 Wall mount housing with transmitter-to- sensor cable connections
5. Tighten all cable glands to obtain optimum sealing.
6. Refer to transmitter FST030 Operating Instructions to program transmitter.