EasyManua.ls Logo

Siemens SITRANS LVS100 - Page 10

Siemens SITRANS LVS100
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page EN-8 SITRANS LVS100/200 – INSTRUCTION MANUAL 7ML19985FT63
mmmmm
English
Process
Temperature
All approvals except CSA Class II,
Group G: –40 to +150 °C (–40 to +302 °F)
CSA Class II, Group G: –40 to +140 °C (–40 to +284 °F), CSA
temperature code T3B
For applications with process temperature greater than +80 °C (+176 °F), the
maximum threaded bushing surface temperature must not exceed +80 °C (+176 °F)
Maximum enclosure surface temperature (Category 2D): +120 °C (+248 °F) (ATEX
relevant)
Maximum extension surface temperature (Category 1D): +150 °C (+302 °F) (ATEX
relevant)
Pressure
max 10 bar, gauge (145 psi, gauge)
Approvals
LVS100
•CE
ATEX II 1/2D
IECEx t IIIC Da/Db
CSA/FM Class II, III, Div. 1, Groups E, F, G
•C-TICK
LVS200
•FM/
C
CSA
US
General Purpose
•CE
CSA/FM Dust Ignition Proof
ATEX II 1/2D
IECEx t IIIC Da/Db
CSA/FM IS Class I, II, III, Div. 1, Groups A to G,
FM Class I, AEx ia IIC, CSA Class 1, Ex ia IIC, available only with 7 to 9 V DC power
supply with NAMUR switch amplifier
ATEX II 1G and 1/2G EEx ia IIC; ATEX II 1D and 1/2D, available only with 7 to 9 V DC
power supply with NAMUR switch amplifier
•C-TICK
Note: SITRANS LVS200 can be installed with an optional temperature isolator
extension. The isolator increases the distance of the electronics from the process
surface, thus allowing for a higher ambient temperature. See “Temperature Isolator
Option (LVS100/200)” on page 11. for more information.
Note: Pressure information for hazardous areas
The device construction allows over-pressure up to 10 bar. This pressure is allowed for
test purposes. The ATEX approval applies to over-pressure between –0.2 and 0.1 bar in
hazardous areas. For higher or lower pressures, the approval is not valid.