EasyManua.ls Logo

Siemens SITRANS SL - 11 Technical Data

Siemens SITRANS SL
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SITRANS SL
Operating Instructions, 12/2010, A5E01132948-04
181
Technical data
11
11.1 Technical data
General
Design Transmitter and receiver units, connected by a sensor
connection cable
Materials
Sensor enclosure: treated aluminium/stainless steel
Process interface: acid-resistant stainless steel
Window: hardened borosilicate glass
Installation In-situ or bypass
Concentration units
ppm
vol %
mg/Nm
3
Display Digital concentration display
(4 digits with floating decimal point)
Laser protection class Class 1, safe to the eye
Analytical performance
Measuring range Internally adjustable
Detection limit at standardized
conditions:
25 °C gas temperature, 1000 hPa
pressure, 1 m path length and
constant ambient conditions.
O
2
: 200 ppm
CO: 0.6 ppm
Minimum measuring range
(at an effective optical path length of
1 m)
O2: 0 ... 1 vol. %
CO: 0 ... 100 ppmv
Maximum measuring range
(measuring range * path length)
O2: 0 ... 150 vol. % • m
CO: 0 ... 2 000 ppmv • m
Calibration verification interval 1 year