Explosion protection
5.1 ATEX
SITRANS SL
Operating Instructions, 12/2010, A5E01132948-04
77
Example: Analog out 0
!6,75$166/
9

&XVWRPHUVLGH
,
PHDV
5
ORDG
Figure 5-7 Using analog output
V
0
must be minimum 7.5 V DC and maximum 30 V DC.
R
load
can be maximum ((V
0
– 7.5 V)/0.025 A) Ω.
Note
The analog outputs of the SITRANS SL are passive and thus must be powered
externally!