Instructions, use and maintenance manual Pag. 19/49
SAU 160-200
10.4.3. Storing the machine
Storage before a long period of inactivity:
• Clean the machine thoroughly.
• Disconnect it from the electrical system.
• If possible, put it back in its original packaging.
10.5. Types and features of the product and of the treated materials
CONDITIONS OF USE:
• Environmental conditions: the machine must be installed inside a lit, ventilated building, on a solid level
support. Temperature from 5 to 40°C with humidity not exceeding 90%.
• Lighting: the light available to the operator must comply with the type of work performed, in relation to general
lighting, according to current regulations and, however, sufficient to read the controls, the hazard signals and
such not to blind the operator.
10.6. Type and features of machine emissions
• Vibrations: in proper operating conditions, the vibrations are not such to give rise to hazardous situations.
• From measurements taken on a SL 120 machine, the results can be deemed valid, by analogy, for all SL
models, with Class 1 integrating sound level meter in the following conditions:
• -) vacuum operated machine at maximum speed of tool (spiral) and of bowl;
• -) microphone located at 1,6m from the ground and 1000 mm from the machine in the points indicated with P1 -
P2 - P3 - P4 in the following figure;
• -) presence of a background noise characterised by an equivalent continuous A-weighted sound pressure level
of 39.0 dB[A].
• It results that the machine emits an equivalent continuous A-weighted sound pressure level of below 70 dB[A],
even taking into account an estimated maximum measurement error equal to 2 dB[A].
•
ATTENTION
Storing the machine outdoors is not allowed.