Instructions, use and maintenance manual Pag. 27/49
SAU 160-200
14.4. System checks
Periodically inspect the operation of machine automation and its earthing. Inspect the methods of operation, the
safety functions, the contacts on the terminal board and the integrity of the cables, of the luminous indicators and of
the earthing.
VERIFICATION:
INTERVAL METHOD
m F, M
14.5. Routine maintenance
Functional check of the operating and emergency controls.
Check the external components of the machine: tools, bowl, protection grid.
Check the belt wear after the first few months of processing.
INTERVAL METHOD
m F,M
1) Periodically grease the machine
through the specific grease nipples.
2) Use food grease, e.g. BECHEM
BELORUB FB19, use a manual
coupling grease pump.
3) For PPE wear shoes with
reinforced tip and non-slip sole,
helmet and goggles.
4) Carefully read the lubricant's
technical data sheet and follow its
instructions.
5) Need to provide adequate
training to maintenance personnel.