7.2 Troubleshooting and Fault Elimination
Faults and warnings can be detected by LED and bus system.
The list “Status Register” helps you eliminate the errors.
6.2.1 LED Indication
Each axis module of the MDD 100 servo drive system has two LED’s for each axis, which
display the status of the corresponding axis.
LED
Description
Green
Red
On
On
Controller in boot mode (no or damaged firmware)
1 Hz flashing
Off
Ready to switch on, no enable
8 Hz flashing
Off
Output current limited by I2T limitation (one or more axes)
On
Off
Running
On
1Hz
flashing
Warning condition
Off
On
Fault condition