AP10
Technical data English
AP10 · Date 10.01.2020 · Art. No. 86832 · Mod. status 6/20
42
Ambient conditions Additional information
EMC EN 61326-1 immunity requirement of indus-
trial applications, emission limit
class B
Safety regulations DIN EN 61010-1 (VDE 0411-1),
UL 61010-1
Limited power supply according
to DIN EN 61010-1 Section 9.4.
Protection class II
Surge category II
Pollution level 2
Protection category IP53 EN 60529, only with mating con-
nectors (Protection category not
tested by UL)
IP65 EN 60529, only with mating con-
nectors (Protection category not
tested by UL)
Shock resistance 500m/s
2
, 11ms EN 60068-2-27
Vibration resistance 100m/s
2
, 5 … 150Hz EN 60068-2-6