UNOCODE 299 Operating manual - English
26 Copyright Silca 2002
5.5 [4] CALIBRATIONS
The following components on the machine have a specific ‘self-setting’ procedure with the use of regulating
templates (Ch.1.5 "Accessories provided", page 7).
- CLAMPS
- CUTTERS
ADAPTERS provided as optionals do not require calibrating. However, if necessary adjustments can be
made to the cutting data, according to the procedures described in Ch.5.5.3 "Manual adjustments", page
30.
In the circumstances listed below (see events) it may be necessary to re-set one or all of the clamps and/
or cutters that the user has in possession. This operation is semi-automatic and requires close attention to
the instructions listed below.
1)
Enter the ‘Calibrations
menu #4
.
Operational keys:
use the arrow keys to move the cursor to the option re-
quired and press ENTER or directly press the numbered key
corresponding to the option number.
2) Select ‘Clamps’ #1.
5.5.1 CALIBRATING THE V100 CLAMP
Before starting the clamp calibration, make
sure that there are no keys and/or adapters
fitted in the V100 clamp.
Operational keys:
SHIFT+ENTER: to select and visualize each side of the clamp
(where applicable).
STOP: to exit the menu.
EVENT MACHINE ZEROES CALIBRATION (chap. 5.5, pag.26)
CLAMPS CUTTERS
Electronic board replacement YES
(see ch.7.6, page 48)
YES
(see ch.7.6, page 48)
YES
(see ch.7.6, page 48)
Replacement of sensors YES NO NO
V100 clamp replacement
(with a new one of the same type)
NO YES NO
Replacement of the cutter shaft SI NO NO
Re-sharpening of existing cutter
and/or cutter replacement
(with a new one of the same type)
YES NO YES
Installation of optional clamps NO YES
(if applicable)
NO
Replacement of the ball screws YES NO NO
1 - Clamps
2 - Cutters
3 - Adaptors
Clamps
V100
V101
V102
1 - Copy by code
2 - List of codes
3 - Queue from PC
4 - Calibrations >>
V100 SIDE A
Adjustment: SIDE A
X = +00 Y = +00
To calibrate [START]
ENTER
ENTER
ENTER
START