UNOCODE 299 Operating manual - English
34 Copyright Silca 2002
Fig. 26
Regulating the Y axis sensor:
•
raise the protective shield
.
• use the provided allen key to loosen the (C1)
grub screw; manually rotate the (C2) rod (fig.
27) in both directions up until the changeover
point from OFF to ON is found.
•
tighten the (C1) grub screw (fig. 27) to
secure the rod
.
Regulating the X axis sensor:
•
carefully tip the machine over
.
• remove the bottom panel by unscrewing all 8
securing screws.
• loosen the (C3) screw (fig. 28, page 35) that
secures the sensor support plate. Manually
move the sensor support plate up until the
display’s description goes from OFF to ON.
• tighten the (C3) screw (fig. 28, page 35) to
secure the plate back into place.
•
re-position the machine back on its
workbench and lower the protective shield
.
•
press
START.
-
the ‘machine’s zero’ settings are de-
tected by electric contact
.
8)
when the operation has been completed,
the display will show the measured quotes
.
9)
press ENTER to save the settings
.
ATTENTION: if the STOP key is pressed, the new settings
will be lost. If so, only the previous setting
values will remain valid.
Z2
Z1
Z2
Y
X
Z2Z1
top view
clamp’s knob
clamp’s bushing
Pos. sensors.
ICX = OFF ICY = OFF
See operating manual.
[START]
Pos. sensors.
ICX = OFF ICY = OFF
See operating manual.
[START]
Pos. sensors.
ICX = ON ICY = ON
See operating manual.
[START]
Pos. sensors.
ICX = OFF ICY = ON
See operating manual.
[START]
Zero detection
in progress!
Measured quotes:
X = 4444 Y = 3333
Save measurements?
No = STOP Yes = ENTER
ENTER
START
START