SIM7000 _Hardware Design _V1.00 2017-05-23
When SIM7000 is in minimum functionality or flight mode, it can return to full functionality by the
AT command “AT+CFUN=1”.
5.4 Current Consumption
The current consumption is listed in the table below.
Table 31: Current consumption on VBAT Pins (VBAT=3.8V)
GNSS
GNSS supply current
(AT+CFUN=0,with USB connection)
Tracking Typical: 34mA
LTE CAT-M1sleep/idle mode
LTE CAT-M1supply current
(GNSS offwithout USB connection)
Sleep mode Typical: 1mA
Idle mode Typical: 11mA
LTE CAT-M1Talk
TBD
TBD
TBD
TBD
LTE CAT-M1data
LTE-FDD B2
@23dbm Typical: 160mA
@10dbm Typical: 116mA
@0dbm Typical: 102mA
LTE-FDD B4
@23dbm Typical: 168mA
@10dbm Typical: 117mA
@0dbm Typical: 113mA
LTE-FDD B12
@23dbm Typical: 167mA
@10dbm Typical: 109mA
@0dbm Typical: 96mA
LTE-FDD B13
@23dbm Typical: 167mA
@10dbm Typical: 109mA
@0dbm Typical: 98mA