EasyManua.ls Logo

Simer 2945 - User Manual

Simer 2945
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OWNER’S MANUAL
Submersible Sump Pumps
NOTICE D’UTILISATION
Pompes submersibles
pour puisard
MANUAL DEL USUARIO
Bombas sumergibles
para sumideros y efluentes
Installation/Operation/Parts
For further operating,
installation, or maintenance
assistance:
Call 800-468-7867 /
800-546-7867
English ...................... Pages 2-7
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
(800) 468-7867 /
(800) 546-7867
Français ................ Pages 8-12
Instalación/Operación/Piezas
Para mayor información sobre
el funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 800-468-7867 /
800-546-7867
Español ............... Paginas 13-19
©2012 SIM846 (07/16/12)
1569 0195
1572 0195 Vert GEN
2943, 2945 2956, 2958
293 Wright Street, Delavan, WI 53115
Phone: 800-468-7867
Fax: 800-390-5351
www.simerpump.com

Questions and Answers

  • C
    Courtney GrahamSep 9, 2025
    What to do if Simer 2945 Water Pump cable leads are not correctly connected?
    • L
      Lisa GreerSep 9, 2025
      If the cable leads of your Simer Water Pump are not correctly connected to the control box, reconnect the leads to match the wiring diagram, ensuring they match the motor lead color code.
  • B
    brian90Sep 8, 2025
    What to do if Simer Water Pump has bleeder orifice valve stuck?
    • T
      Taylor MannSep 8, 2025
      If the bleeder orifice check valve in your Simer Water Pump is stuck (standard tank only), free the valve. If it's installed backwards, reverse it.
  • J
    jasonbennettSep 6, 2025
    What to do if Simer 2945 Water Pump check valve is stuck?
    • A
      Andrew ThomasSep 7, 2025
      If the check valve at the pump discharge of your Simer Water Pump is stuck, free the check valve.
  • A
    Andrew JohnsonAug 22, 2025
    What to do if Simer Water Pump has low voltage?
    • A
      Anthony GomezAug 23, 2025
      If your Simer Water Pump is experiencing low voltage, you can try installing a larger wire from the meter to the control box and from the control box to the pump. If the issue persists, it may be necessary to have the power company raise the supply voltage.
  • D
    Dana HughesSep 4, 2025
    How to fix Simer 2945 with broken wire in control box?
    • J
      Jonathan HarrisSep 4, 2025
      To fix a broken wire in the control box of your Simer Water Pump, disconnect the power and then repair or replace the faulty wire.
  • R
    Robert WebbSep 3, 2025
    What to do if Simer 2945 Water Pump has pressure switch problems?
    • R
      Rachael JohnsonSep 3, 2025
      If you are experiencing issues with the pressure switch of your Simer Water Pump, you can try to re-adjust or replace the pressure switch.
  • R
    Ryan OconnorSep 2, 2025
    What to do if Simer 2945 Water Pump has no voltage at pressure switch?
    • J
      james39Sep 2, 2025
      If there's no voltage at the pressure switch for your Simer Water Pump, replace the faulty pressure switch.
  • J
    Joe OsborneSep 1, 2025
    What to do if Simer Water Pump's pressure switch is too far from tank?
    • G
      Gary EdwardsSep 1, 2025
      If the pressure switch of your Simer Water Pump is too far from the tank, move the switch to within one foot of the tank.
  • P
    psimmonsAug 31, 2025
    What to do if Simer Water Pump has plugged intake screen?
    • M
      Michelle JonesAug 31, 2025
      If your Simer Water Pump has a plugged intake screen, clean or replace it as necessary.
  • M
    mitchell43Aug 29, 2025
    What to do if Simer 2945 Water Pump has tank waterlogged?
    • N
      Nancy ReevesAug 30, 2025
      If your Simer Water Pump's tank is waterlogged: * For pre-charge tanks, adjust the air pressure to 2 PSI (13.8 kPa) less than the pump cut-in pressure when there is no water pressure on the system. Replace the bladder if necessary. * For air over water tanks, repair or replace the tanks and replace the snifter valves if needed.

Simer 2945 Specifications

General IconGeneral
Cable length10 m
Voltage230 V
Maximum delivery height6 m
Maximum particle size3 mm
Maximum delivery rate300 l/min
Motor power290 W
Max Flow Rate300 l/min
Max Head6 m