CE34/44/54 Setup menu Chapter 8-7
8.4 Speed alarm, units & language
MENU
Call up the menu bar, and...
6,1
load Speed alarm, units & language display
Setup for speed:
Speed alarm maximum (SOG):000.0kn OFF
Speed alarm minimum (SOG):000.0kn OFF
The display
example
sections are
for:
CE34/44/54
Setup for units:
Depth/altitude in: METERS
Distance in: NAUTICAL MILES
Speed in: KNOTS
Temperature in: DEGREE CELCIUS
Software version: CE34 2.20
Serial number: 0x00100003
Interface software version: 1.17
GPS receiver type: N11999
PAGE rotation interval: 05 sec.
Display text in: English GB
CE34
MENU
Exit Accept
ENT
Software version: CE44/54 2.20
TL50 version: Not connected
AT44 version: HW rev.: 2, SW: 12.34
GPS receiver type: N12000
PAGE rotation interval: 05 sec.
Display text in: English GB
CE44/54
MENU
Exit Accept
ENT
Scroll up/down to go to the function you wish to change
0-9
Key in new values, or...
+/-
Toggle between available values
ENT
Confirm changes, or...
MENU
exit function without making any changes
Speed alarm - can be set to maximum and/or minimum cruis-
ing speed. This may be handy for trawl fishing, entering harbors
with speed limits, etc. Speed stability and time of response can be