Page 23
5. INSTALLATION INSTRUCTION
5.1 LOCATION REQUIREMENTS
5.1.1 ENVIRONMENT REQUIREMENTS
Cycraft is designed for indoor use and should never be installed outdoors.
Environment and facility requirements are as follows:
Installation location Indoor use only
Ambient temperature 5 to 40 C
Humidity 10 to 70 % (no condensing)
Min. Entrance
dimensions
1540 mm (W) x 2100 mm (H)
Min. Ceiling Height 2400 mm (H)
Min. Footprint
(incl. Fence)
4050 mm (L) x 2900 mm (W)
Min. Floor Loading 310 kg/m
2
Cleanliness Free of dust and debris
l Never install the game machine outdoors
Also avoid the following locations even though they are indoors.
l
humidity that can condense
l Close to an indoor pool or showers
l Exposed to direct sunlight
l Exposed to direct heat, such as close to a heater vent, or in a highly heated
room
l Close to flammable or volatile chemicals, or dangerous materials
l Avoid floors that slope(any slope more than 2 degrees)
l Avoid strong vibrations
l Avoid dusty locations
l Avoid any location that does not allow enough space around the machine