EasyManua.ls Logo

Simuline Cycraft - Setting the Safety Sensor Parameters

Simuline Cycraft
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 51
All settings through the LCD panel can be made only when the system is powered up
in the maintenance mode”. This mode is entered by first putting the Maintenance
Switch in the operation panel in the “Maintenance” position and powering up the
system. After the maintenance mode is entered, configuration and settings can be
made as described in the following sub-sections.
6.5.1 SETTING THE SAFETY SENSOR PARAMETERS
1) Bring up the configuration main menu by pressing the MENU/SET button for 2
seconds.
2) Highlight the 4. Sensor Usage” item by using the UP and DOWN buttons. The
highlighted item is indicated by the “=>” sign.
3) Press MENU/SET button to bring up the Sensor Usage sub-menu.
Each of the items in the above list can be enabled or disabled. For example, to
disable the floor and photo sensors, highlight item 1, press the MENU/SET button,
and use the UP and DOWN switches to toggle to the “OFF” setting.
4) After setting the sensor, press the ESC button to go to the previous upper level
menu until the main menu is displayed.
5) Highlight “4. Exit” and press MENU/ESC for three seconds to fix the settings and
exit the menu.
=> 1. Safety sensor
2. Seat belt
3. Motion stop
4. Exit
Sensor Usage Sub-Menu
[MAINTENANCE MODE ]
=>1. DIOTEST
2. MOTION TEST
3. SETUP TCP/IP
4. SENSOR USAGE
5. STATISTICS
6. MOTION LEVEL
7. FALLING DETECT
8. EXIT
Configuration of LCD Main
Menu

Table of Contents

Related product manuals