properly. Rotate the volume knob on
the rear of the right speaker.
5
The LCD screen on the SCU does
not show any message after
power up.
Motion base does not
initialize( when initializing, cabin
moves slightly with jerks).
Motion Board boot-up
failure.
Open the door on the rear of
the SCU.
Hook up the extra monitor,
Keyboard, mouse to the
connectors labeled “Motion
Board”. Check if the Motion
Board boots up normally.
If Motion Board has problem ,
contact technical support
center for replacement.
6
The simulator does not initialize.
Controller module may have
malfunction
Check the error message
appeared on the LCD of the
SCU.
Refer to the controller error
message list
7
Some area on the cabin monitor
has strange color
The display is out of position or
distorted.
The monitor may be
magnetized.
The monitor may not be
adjusted properly.
Press the degaussing switch
on the monitor adjustment
control pad inside the cabin
front beside monitor.
Adjust the monitor as the
screen instructions with the
control panel.
8
Sound is too loud or low
Vibration level on the seat is too
high or low
The sound level is not
adjusted properly.
Change the volume setting on
the back side of the operator
panel.
9
Steering wheel turns either to the
left or to the right and then locks
The Steering potentiometer
may malfunction
Contact technical support
center and ask for
replacement.
10
Coins is rejected
Coins may be jammed Reset the machine by
powering down and up.

Table of Contents