EasyManua.ls Logo

Sinoboom 1323RE - Preparation

Sinoboom 1323RE
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Jun. 2021 6-4 1323RE&1623RE Operation Manual
PRE-OPERATION FUNCTION TEST
Figure 6-2 Ground controller (Sinoboom control system)
Table 6-2
1. Hour meter
7. Neutral position 13. Platform up switch
2. Emergency stop button 8. Natural gas switch (not used) 14. Platform up/down enable switch
3. Platform control position
9. Engine speed select switch (not
used)
15. Emergency lowering
combination switch
4. Key switch (Ground/Platform
select switch)
10. Glow plug switch (not used)
16. Platform down switch
5. Ground control position 11. Ignition switch (not used)
6. Buzzer 12. LED screen
UNSAFE OPERATION HAZARD
Unless in emergency situations,
never operate the machine from
the ground controller if there is
any person on the platform.
Never operate the machine if any
control handle or switch that
controls the platform movement
is not returned to the OFF position
after being released.
PREPARATION
1. Select a firm, level test surface free of obstructions.
2. Turn the Ground/Platform select switch on ground
controller to Ground control position.
3. Pull out the emergency stop button on ground
controller to ON position.
4. Ensure the LCD screen is lit, and then
“System Loading…”, 星邦智能高空作业平台 (-
Sinoboom Intelligent Aerial Work Platform), and the
angles in X-axis and Y-axis of chassis are displayed
successively.
CAUTION
POWER
!
T T
2
3
5
4
12
16
7
8
9
10
11
13
15
16
14

Table of Contents

Related product manuals