© Jun. 2021 6-14 1323RE&1623RE Operation Manual
PRE-OPERATION FUNCTION TEST
5. The other 3 wheels should come in close contact
with the ground.
• With the machine in operating position:
1. Start the machine from the platform controller
and select the high idle speed.
2. Using the platform lift function, raise the platform
until the lower limit switch disengages.
3. Drive the machine to allow the left steer wheel to
stand on a 10cm (3.9in) high block or kerb.
4. The other 3 wheels should come in close contact
with the ground.
5. Drive the machine to allow the right steer wheel
to stand on a 10cm (3.9in) high block or kerb.
6. The other 3 wheels should come in close contact
with the ground.
TESTING THE WEIGHING
SYSTEM
1. Before conducting this test, fully lift and lower the
platform twice to ensure normal lubrication of the
slider and track.
2. Lower the platform to the minimum height and
retract the extension platforms. With the scissor
arm fully retracted, gradually add a load to the
platform.
Table 6-5
Mdoels Test Results
1323RE
When the weight does not exceed 680 kg (1499 lb), ensure that the platform is able to lift to the
highest position.
When the platform load is greater than or equal to 815 kg (1797 lb), the platform lifting height
should be no greater than 3.2±0.5 m(10ft 20in±1ft 25in).
1623RE
When the weight does not exceed 680 kg (1499 lb), ensure that the platform is able to lift to the
highest position.
When the platform load is greater than or equal to 815 kg (1797 lb), the platform lifting height
should be no greater than 3.2±0.5 m(10ft 20in±1ft 25in).
Note:The hydraulic oil viscosity will increase as the
temperature reduces, which may adversely affect the
pressure sensing.If the new machine operates at
temperature conditions that differ with the OEM factory
temperature by more than 10°(50°F), or the hydraulic
oil temeperature is below 15°(59°F), the overload alarm
may be triggered (the display screen on platform or
ground controller indicates “OL”) even if the platform
load does not exceed the rated load, in this
circumstance, please re-calibrate the weight sensor.