© Oct 2020 6-28 AB18EJ&18HJ Maintenance Manual
REPAIR PROCEDURES
Fault
code
Description
Cause Check
0045
Pot-low overcurrent of
pump motor controller
Excessively low resistance
of potentiometer.
Overcurrent at potentiometer low end, replace
if necessary
0145
Pot-low overcurrent of FL
motor controller
0245
Pot-low overcurrent of FR
motor controller
0345
Pot-low overcurrent of RL
motor controller
0445
Pot-low overcurrent of RR
motor controller
0046
Invalid EEPROM of pump
motor controller
1. Software error;
2. Controller failure.
1. Download the correct software version;
2. Replace the controller.
0146
Invalid EEPROM of FL
motor controller
0246
Invalid EEPROM of FR
motor controller
0346
Invalid EEPROM of RL
motor controller
0446
Invalid EEPROM of RR
motor controller
0047
Operation sequence error
of pump motor controller
1. Input sequence error of
keyswitch, interlock
switch, directional
switch and accelerator;
2. Failure of keyswitch,
interlock switch,
directional switch and
accelerator;
3. Improper wiring.
1. Check the input sequence of switches to
exclude the operation-induced cause;
2. Use a handhold unit to check each switch
condition;
3. Use a handhold unit ot check the
accelerator signal;
4. Replace the failed switches.
0147
Operation sequence error
of FL motor controller
0247
Operation sequence error
of FR motor controller
0347
Operation sequence error
of RL motor controller
0447
Operation sequence error
of RR motor controller
0049
Setup change of pump
motor controller
The key switch must be
restarted after setup
change of some
parameters.
Restart the key switch to eliminate the fault.
0149
Setup change of FL motor
controller
0249
Setup change of FR motor
controller
0349
Setup change of RL motor
controller
0449
Setup change of RR motor
controller
0068
VCL run error of pump
motor controller
Software problem
1. Update the software to the correct version;
2. Replace the controller.
0168
VCL run error of FL motor
controller