SAFETY
ELECTRICAL SHOCK HAZARDS
• Always maintain a safe distance
from power lines and electrical
equipment in accordance with ap-
plicable government regulations
and see Table 3-1 , page 3-2.
• Consider platform movement,
wire swinging or drooping, be-
ware of strong winds or gusts,
and do not operate the machine
when there is lightning or heavy
rain.
• If the machine comes into contact
with live wires, keep away from
the machine. Personnel on the
ground or on the platform must
not touch or operate the machine
until the power is switched off.
• Do not use the machine as a
ground wire during welding and
polishing operations.
Table 3-1
Voltage
(Phase to Phase, kV)
Minimum Safe Distance
(m/ft)
0-50 3.05 (10)
50-200 4.60 (15)
200-350 6.10 (20)
350 -500 7.62 (25)
500 -750 10.67 (35)
750 -1000 13.725 (45)
TIPPING HAZARDS AND
RATED LOAD
Maximum rated load bearing capacity of the platform:
Table 3-2
GTJZ0608E
Retracting 380kg(838 lb)
Extending: Stationary only 260kg(573 lb)
Extending: Extension only 120kg(265 lb)
GTJZ0808E
Retracting 250kg(551 lb)
Extending: Stationary only 130kg(286 lb)
Extending: Extension only 120kg(265 lb)