© Mar. 2022 3-2 GTTZ10EJ Operation Manual
SAFETY
ELECTROCUTION
HAZARDS
NOTE: This machine is not insulated and does not
have an electric shock protection function.
All operators and managers shall comply with national
or local regulations regarding the minimum safe
distance of live conductors above the ground. In the
absence of such requirements, operators and
managers should follow the minimum safety distance
requirements in Table 3-1 Minimum Safe Distance,
page 3-2.
ELECTRICAL SHOCK HAZARDS
Always maintain a safe distance
from power lines and electrical
equipment in accordance with
applicable government
regulations and see Table 3-1
Minimum Safe Distance, page 3-2.
Consider platform and boom
movement, wire swinging or
drooping, beware of strong winds
or gusts, and do not operate the
machine when there is lightning
or heavy rain.
If the machine comes into contact
with live wires, keep away from
the machine. Personnel on the
ground or on the platform must
not touch or operate the machine
until the power is switched off.
Do not use the machine as a
ground wire during welding and
polishing operations.
Table 3-1 Minimum Safe Distance
Voltage
(Phase to Phase, kV)
Minimum safe distance
(m/ft)
0-50 3.05 (10)
50-200 4.60 (15)
200-350 6.10 (20)
350 -500 7.62 (25)
500 -750 10.67 (35)
750 -1000 13.725 (45)
TIPPING HAZARDS AND
RATED LOAD
Maximum rated load bearing capacity of the
platform:200kg (440lb)