How to avoid test method error on Sinocare Safe AQ Smart Blood Glucose Meter?
- EElizabeth HurleySep 2, 2025
To avoid errors with your Sinocare Blood Glucose Meter, insert the test strip into the meter before applying the sample to the strip.
How to avoid test method error on Sinocare Safe AQ Smart Blood Glucose Meter?
To avoid errors with your Sinocare Blood Glucose Meter, insert the test strip into the meter before applying the sample to the strip.
What to do when Sinocare Safe AQ Smart shows low battery?
When your Sinocare Blood Glucose Meter indicates low battery power, replace the battery.
Why Sinocare Safe AQ Smart shows error with expired test strip?
If you encounter issues with your Sinocare Blood Glucose Meter, it may be due to an expired or damped test strip. Use a new test strip to test again.
How to correctly insert test strip in Sinocare Blood Glucose Meter?
To ensure proper function of your Sinocare Blood Glucose Meter, insert the test strip correctly with the printing facing up. Push it into the strip port until it stops.
Why does my Sinocare Safe AQ Smart Blood Glucose Meter not work with a used test strip?
If you are getting errors using a test strip with your Sinocare Blood Glucose Meter, use a new test strip to test again.
How to troubleshoot no display on Sinocare Safe AQ Smart Blood Glucose Meter?
If your Sinocare Blood Glucose Meter has no display, remove the battery, wait for 3 minutes, and then reinstall it.
What to do if Sinocare Safe AQ Smart doesn’t start after applying blood?
If your Sinocare Blood Glucose Meter doesn’t begin testing after you apply a blood sample, it might be due to an insufficient blood sample. Repeat the test using a new test strip and ensure you apply enough blood.
Specifies the intended application and scope of the blood glucose monitoring system.
Describes the scientific method used by the meter to measure glucose levels.
Explains how to enable and manage the voice output feature on the Safe AQ Voice meter.
Provides a step-by-step procedure for conducting a control solution test.
Lists common issues, their probable causes, and recommended actions for incorrect results.
The Safe AQ Smart, Safe AQ Air, and Safe AQ Voice Blood Glucose Monitoring Systems are designed for the quantitative measurement of glucose in fresh capillary whole blood samples taken from the fingertip and in venous whole blood samples. These systems are intended for in vitro diagnostic use, for self-testing and professional use as an aid in the management of diabetes. They are not intended for the diagnosis or screening of diabetes, for neonatal (newborn or infant) use, for use on critical patients, or for alternative site testing (AST) use.
The blood glucose test is based on the measurement of electrical current generated by the reaction of glucose with special chemicals on the test strip's electrode. A blood or control solution sample is drawn into the test strip tip via capillary action. Glucose in the sample reacts with the chemicals, producing electrons and electrical current. The meter measures this current and calculates the glucose result, displayed in mg/dL or mmol/L. Each meter displays only one unit of measurement, which is preset and cannot be changed.
The Safe AQ Smart, Safe AQ Air, and Safe AQ Voice meters store up to 10 blood glucose test results in memory. Once 10 results are stored, adding a new result will delete the oldest one. To review results, with the meter off, press the main button for 1.5 seconds to turn it on. The meter will beep and display the last blood glucose test result. Briefly pressing the button again allows you to review previous results. Pressing the button for 3 seconds turns the meter off. Note that results cannot be reviewed when a test strip is in the port.
| Measurement Range | 20-600 mg/dL (1.1-33.3 mmol/L) |
|---|---|
| Sample Type | Capillary Whole Blood |
| Blood Sample | Fresh capillary whole blood |
| Test Time | 5 seconds |
| Memory Capacity | 1000 test results with date and time |
| Power Source | Battery |
| Display | LCD |
| Weight | Approx. 50g (without batteries) |
| Battery Type | 2 x AAA alkaline batteries |
| Sample Volume | 0.6 microliters |
| Battery | 2 x AAA alkaline batteries |