KFGC (CAN bus) fault notifications
Fault Category Possible cause Rectification
Short-circuit fault Malfunction
Damaged cable or plug
Incorrect installation
Replace the cable.
Check the electrical installation.
Temperature fault Malfunction
Ambient temperature too high
Output power too high
Check system for line blockage and lubricant for feedability.
Let pump unit cool down.
Motor current fault Malfunction
Partial or total blockage of motor shaft
and/or agitator
Check the agitator for freedom of movement.
Check whether objects in the grease reservoir
are impeding the agitator.
Check the lubricant for feedability.
Open input/output Warning
Input/output was configured but the
component it was configured for is
not connected
Check the configuration.
Check whether all configured components are attached.