Technical data
Description Value
KFG(S) 1-5 KFG(S) 3-5 KFG(S) 5-5
Weight see page 35 see page 35 see page 35
Reservoir material PA 6I PA 6I PMMA
12/24 VDC 90...264 VAC
Permissible operating
temperature range
-25 °C to +75 °C -25 °C to +60 °C
Electrical values See Chapter 6, "General conditions for connections," and page 41
Protection class
according to DIN 40050, T9
IP56 IP56
Operating mode/ON-time
according to VDE0530/ DIN 41756
S1 continuous
operation
At -25 °C to 40 °C: S1 continuous operation at 40 °C to 60 °C:
Run time 0 to 10 min. minimum interval time = 4 x run time (20% ON-time)
Run time 10 to 15 min. minimum interval time = 2 h
Data universally applicable to KFG, KFGS; KFGC
Max. back pressure 300 bar
Max. number of outlets (if less
than 3 outlets are required, close
unneeded outlets with screw plugs)
3
Delivery rates [cm
3
/min] KFG1.U1 = 2.5 KFG1.U2 = 1.8 KFG1.U0 = 5.0 at max. 200 bar
KFG1.U3 = 1.3 KFG1.U4 = 0.8
Lubricant NLGI Grade 1 to 2 greases with EP additives, compatible with plastics, NBR elastomers, copper and copper
alloys, and NLGI Grade 000 to 0 fluid greases
Flow pressure Up to max. 700 mbar
16. Technical data