External control units
Application Type designation
Order number
Features
Piston distributor for single-line
systems
EXZT2A02-E Pulse generator/counter with adjustable interval time, interval time extension,
monitoring of pressure build-up and reduction, and fill level monitoring
Piston distributor for single-line
systems
EXZT2A03-E Pulse generator/counter with selectable monitoring time, monitoring of fill level and
pump cycle time (stroke monitoring), adjustable delay time, and interval time extension
Progressive systems EXZT2A05-E Pulse generator/counter with adjustable interval time, interval time extension,
pressure build-up monitoring, pulse monitoring, and fill level monitoring
Progressive systems EXZT2A06-E Pulse generator/counter with selectable monitoring time, monitoring of fill level and
pump cycle time (stroke monitoring), adjustable delay time, interval time extension, and
pulse monitoring
Piston distributor for
single-line systems
EXZT2A07-E Pulse generator/counter with adjustable interval time, interval time extension,
pressure build-up monitoring, fill level monitoring, and fill level pre-warning
Electronic timer for centralized
lubrication systems
IG351-10-E Pulse generator with adjustable interval time, adjustable pump cycle time, and fill level
monitoring with NO-contact
Piston distributor for single-line
systems
IGZ38-30-E Pulse generator/counter with adjustable interval time and pressure build-up monitoring,
and fill level monitoring with NC contact (wire breakage monitoring)
Piston distributor for single-line
systems
IGZ36-20-E Pulse generator/counter with adjustable interval time, monitoring of pressure build-up
and reduction, and adjustable delay time
Piston distributor for single-line
systems
IGZ36-20-S6-E Same as IGZ36-20-E, but with full level monitoring with NC contact
(wire breakage monitoring)