Modbus registers
Lubrication status Modbus function code (FC3)
NOTE
FC3 might give time-out response after writing a value
REGISTER
[channel1]
REGISTER
[channel2]
R/
W
TYPE
PARAMETER
2065
2081
R
Integer
Current status of the lubrication channel
0= not configured
1= lubrication interval
21= pressuring line 1
22= pressuring line 2
3= interlocking
4= closed
5= discharge delay
6= low level alarm
71= pressure alarm line 1
72= pressure alarm line 2
8= discharging
9= waiting another channel to complete
60= Doser indicator alarm
62= Air alarm in grease spray
2066,2067
2082,2083
R
Longint
Elapsed time of current status [s]
2068
2084
R
Integer
Current pressure in bars in line 1
2069
2085
R
Integer
Current pressure in bars in line 2
2070
2086
R
Integer
Lubrication counter