41
6.4.1 Settings
Lubrication settings Modbus function code (FC16)
REGISTER
[channel1]
REGISTER
[channel2]
R/
W
TYPE
PARAMETER
34-38
66-70
R/
W
String
free name of the channel
40
72
R/
W
Integer
Lubrication cycle in minutes or in
pulses
41
73
R/
W
Integer
Maximum pressuring time in seconds
42
74
R/
W
Integer
Low limit pressure in bars
43
75
R/
W
Integer
High limit pressure in bars
44
76
R/
W
Integer
Configured lubrication mode
1= OS (oil )
2= SG1 (single line grease)
3= SG2 (dual line grease)
5= SG2E (dual line hold)
7= ML1 (single line MultiLube)
8= ML2 (dual line MultiLube)
9= SG1E (single line hold)
10=S1 (single line grease spray)
11=S2 (dual line grease spray)
12=P1 (progressive system)
48
80
R/
W
Integer
Pressure switch=0
or pressure transmitter =1 in use
49
81
R/
W
Integer
Discharge delay factor when pressure
switches are in use
50
82
R/
W
Integer
Lubrication cycle counted as time=0 or
pulses =1
51
83
R/
W
Integer
LG-IND doser indicators in use
0=NO
1=YES
52
84
R/
W
Integer
Air control in use in grease spray
system
0=NO
1=YES