DA 2000
14 Technical User Guide
3.6 Before starting the pump
Remove transport plug and mount the supplied oil pin with
ventilation.
Check pump oil level.
Pump without frequency converter
Turn on the water and bleed the filters by means of the air
screws at the top of the filters.
Pump with frequency converter
Turn on the water and start the pump in manual, bleed the
filters by means of the air screws at the top of the filters.
3.7 Start/stop
Without frequency converter
Automatic control:
Start the pump by turning the Man-0-Auto button to Auto.
An external climate controller now controls the start/stop
function.
Manual control - service:
Start the pump by turning the Man-0-Auto button to Man-
ual. The pump runs constantly until it is stopped manu-
ally.
Stop the pump:
Stop the pump by turning the Man-0-Auto button to 0.
Reconnection after motor overload. Press the blue reset
button.
With frequency converter
The main switch (repair switch) is turned to ON. You then
either choose manual operation or automatic operation as
in connection with the pump without frequency converter.
In case of overload, you turn the main switch to OFF and
back to ON in order to restart the pump.