DA 2000
16 Technical User Guide
4 Installation guide
4.1 Electrical connection
Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.
The installation of a power supply isolator is required for each motor and power supply to facilitate
voltage-free work on the electrical equipment. The power supply isolator is not included.
Incorrect connection of the high-pressure cooling pump may result in fatal electric shock. The
pump must be connected only to an earthed electrical circuit.
A RCD must be installed in front of the high-pressure cooling pump.
The pump has a 2.5 m cable with CE connector.
The connection box is equipped with cable gland.
An electronic calcium decomposer must be continuously connected to 230 V AC.