DA 2000
36 Technical User Guide
8.2 DA 2000 pumps with frequency converter
437160 437161 437162 437163
Electrical
Rated voltage
V 3x400 3x400 3x230 3x400
Operating voltage
V AC 380-415 380-415 220-240 380-415
RCD
To be installed in accordance with applicable laws and
standards. RCD 300 mA (type B) may be used in front of
the supply voltage for frequency regulated pumps.
Frequency
Hz 50/60
Current consumption
A 5.2 5.2 15.1 8.9
Input power P1
kW 3.7 3.7 6.2 6.2
Input power P2 shaft
kW 2.2 2.2 4 4
Mechanical
Volume
l/min 6 12 21 21
Min. flow
% 5
Max. pressure
bar 70
Working pressure
bar 70
Min. pressure water supply at
max. capacity
bar 2
Standard filters
micron 1 and 5
Coarse filter (auxilliary equip-
ment)
micron 25 - 10
Sound pressure level (with
cover)
at 100 % performance
at 50 % performance
at 20 % performance
at 5 % performance
dB(A)
74.5
59
58
55
Oil type (mineral oil)
SAE 15W-40
Environment
Temperature, operation
°C 0 to +40
Storage temperature
°C 0 to +40
Ambient humidity, operation
% RH 85
Protection class
IP 54
Shipment
Dimension HxWxD
mm 850x650x500
Dimensions when packed
HxWxD
mm 1200x800x600
Weight
kg 46.2 47.8 64 61.2
Shipping weight