DC Electric Full-size RTs
December 2007 Page 25
Section 2 - Operation Visual and Daily Maintenance Inspections
Electrical Panel
Hydraulic Pump/Motor
Assembly
Main Manifold
Brake Manifold
Base Control
Switches
2.8-6 Hydraulic/Electrical Compartment
Ensure all compartment latches are secure
-
and in proper working order.
Electrical Panel•
Ensure panel is properly secured and -
there is no visible damage.
Ensure there are no loose wires or -
missing fasteners.
Manifolds•
Ensure all fittings and hoses are properly
-
tightened and there is no evidence of
hydraulic leakage.
Ensure there are no loose wires or -
missing fasteners.
Tilt Sensor•
Ensure tilt sensor is properly -
secure and there is no visible
damage.
Base Control Switches•
Ensure there are no signs of visible
-
damage and all switches are in their
neutral positions.
Emergency Lowering Access Rod•
Ensure rod is properly secured and there -
is no visible damage.
Tilt Sensor