SMA Solar Technology AG Electrical Connection
Installation Guide SB13_21TL-IA-IEN121060 31
3. Ensure the cable is correctly in place.
4. Push the bolted connection toward the thread and fasten to a torque of 2 Nm.
☑ The DC connectors are now assembled and can be connected to the inverters, as described in
section 5.4.4"Connecting the PV Array (DC)" (page33).
Result Measure
☑ If the conductors are visible in the hollow
cavity of the clamping clip, the cable is in
the correct position.
• Proceed to step 4.
☑ If the conductors are not visible in the
hollow cavity, the cable is not in the correct
position.
• Loosen the clamping clip. For this purpose,
use a screwdriver with a width of 3.5 mm.
• Remove cable and start again from step 1.